insightcas.blogg.se

Ge networx caddx controls nx1324 manual
Ge networx caddx controls nx1324 manual









ge networx caddx controls nx1324 manual

SELECTING THE MODULE TO PROGRAM: Since all modules connected to the NX-8 are programmed through the keypad, the module you are You are now in the Program Mode and ready to select the module to program. If it rejects the code, the sounder will beep 3 times, Note for NX1300 Series LED Keypad: The zone lights will illuminate indicating the first digitĬode" is valid, the "Service" LED will flash and the five function LEDs will illuminate steady. 3) Enter the new user code designated for that individual - The "Ready" LED will flash indicating that the code was accepted. Set keypad options 1) Enter - The "Service" LED will flash. 2) Enter the zone number (1 - 48) you want the keypad to start at. Each time a zone is faulted, the zone light on the LED keypad will illuminate and the chime will During this test the chime light will flash on the LED keypad. , entering followed by a user code will allow a walk-through zone test where all zones become silent and local (non-reporting). Manual Test- The NX-8 can be programmed to perform a bell and/or communicator test when Lost Clock Service Light- The NX-8 can be programmed to illuminate the "Service" LED when the internal clock has an invalid time due to power loss.

ge networx caddx controls nx1324 manual

Group Bypass - A designated group of zones can be programmed to bypass by pressing If it is not reported, this condition will illuminate the "Service" LED on the keypad. (Seeįault- If the NX-870 is used, a fault of the earth ground can be reported to the central station. This condition can be reported to the central station.

ge networx caddx controls nx1324 manual

(See the terminal description on page 56 and locations 45-50, page 25)Īuxiliary Power Overcurrent- The NX-8 will illuminate the "Service" LED on the keypad whenever too much current is drawn from any device powered by the system. The NetworX design allows a fully loaded system to be Software that allows up to 99 users to interface with 48 zones, 8 partitions, and a host of integrated fire, access, verification, and input/output modules, all reported with the most comprehensive and fast SIA and Contact ID formats. 11 LOADING FACTORY DEFAULTS.13 ENROLLING MODULES AND KEYPADS.13 5 PROGRAMMING THE LED KEYPADS.9 PROGRAMMING THE NX-8 CONTROL PANEL 11 TYPES OF PROGRAMMING DATA. # These wireless devices are only UL listed for residential applications. ** These products have not been tested and approved by Underwriters Laboratories, Inc. NX-8 CONTROL PANEL Installation and StartupĨ Zone LED Door Design Keypad 16 Zone LED Door Design Keypad 24 Zone LED Door Design Keypad 48 Zone Fixed Language Icon Keypad











Ge networx caddx controls nx1324 manual